Jinhong.co.kr

COPAL ELECTRONICS
FEATURES
Excellent stability
Compatible with
State of the art sensor and circuit technology guarantees EMC directive
Super long battery life
A 3.6 V lithium battery incorporated has the long life to lastover 3000 hours.
Automatic power off
Automatic power off function works in approximately 3minutes, which minimizes battery waste.
Handy size and easy one hand operation
Easy reading with a large LCD display
No reading error because of digital display with the holdingfunction.
Meet EMC standard
MODEL NUMBER DESIGNATION
Pressure referenceG : GaugeGH : GaugeVH : Gauge (Vacuum) 0 ~ 10 kPa (When displayed in the unit of Pa) 0 ~ 100 kPa (When displayed in the unit of Pa) 0 ~ 1 MPa (When displayed in the unit of Pa) ❈ Please refer to the LIST OF MODEL NUMBERS when placing orders.
Specifications are subject to change without notice. Specifications in this catalog are for reference. The formal specification sheets will be submitted upon request.
COPAL ELECTRONICS
LIST OF MODEL NUMBERS
<Pa version>

Pressure reference
Absolute
Rated pressure range kPa
0 ~ 100
100 kPa abs
Unit of display
Part number
Unit of display
Part number
The GMP version, marked A is manufactured upon receipt of order basis.
<Compound pressure version>
Pressure reference
Rated pressure range kPa
10 ~ 10
100 ~ 100
100 ~ 1000
Unit of display
Model number
<Non SI unit version>
The new Japanese measurement Law of November 1993 prohibits the use of non SI units as from October 1999.
The standard pressure unit used for the product manufactured and sold after October 1999 will become Pa.

Pressure reference
Absolute
Rated pressure range
0 ~ 98.1
0 ~ 98.1 kPa abs
kPa {kgf/cm2}
{0 ~ 1000 mmH2O}
{0 ~ 735 mmHg} {0 ~ 735 mmHg}
{0 ~ 735 mmHg abs}
Unit of display
Part number
❈ Verify the above model numbers when placing orders.
<Option>
● The soft carrying case for PG-100 – Order item: PG-100 soft carrying case
(Useful for when carrying out and keeping.) ● DC3.6 V lithium battery – Order item: Lithium battery
(The battery is an expendable item. The first one is provided with the unit.) The soft carrying case for PG-100 (Option) Specifications are subject to change without notice. Specifications in this catalog are for reference. The formal specification sheets will be submitted upon request.
COPAL ELECTRONICS
STANDARD SPECIFICATIONS
<Pa version>
● Unless otherwise specified, the specs are defined at an ambient temperature of 25±5 °C.
Absolute
General specifications
− 20 ~ 70 (Atmospheric pressure, humidity 65 %RH maximum) Lithium battery DC3.6 V Battery life 3000 h minimum ± 0.5 %F.S. ± 2 digits (at 25 °C ± 5 °C) Auto power off (3 min), Display hold, Battery replacement display Attachements : Half union (for a tube of φ 6 O.D.),and Barb fitting (for a tube of φ 4 I.D.), one piece each.
❈ The value out of rated pressure range can be displayed, but the accuracy is not guaranteed.
Specifications are subject to change without notice. Specifications in this catalog are for reference. The formal specification sheets will be submitted upon request.
COPAL ELECTRONICS
STANDARD SPECIFICATIONS
<Compound pressure version>
● Unless otherwise specified, the specs are defined at an ambient temperature of 25±5 °C.
General specifications
− 20 ~ 70 (Atmospheric pressure, humidity 65 %RH maximum) Lithium batteryDC3.6 V Battery life 3000 h minimum Auto power off (3 min), Display hold, Battery replacement display Attachements : Half union (for a tube of φ 6 O.D.), and, Barb fitting (for a tube of φ 4 I.D.), one piece each.
Specifications are subject to change without notice. Specifications in this catalog are for reference. The formal specification sheets will be submitted upon request.
COPAL ELECTRONICS
STANDARD SPECIFICATIONS
<Non SI unit version>
The new Japanese measurement Law of November 1993 prohibits the use of non SI units as from October 1999.
The standard pressure unit used for the product manufactured and sold after October 1999 will become Pa.

● Unless otherwise specified, the specs are defined at an ambient temperature of 25±5 °C.
Absolute
General specifications
− 20 ~ 70 (Atmospheric pressure, humidity 65 %RH maximum) Lithium battery DC3.6 V Battery life 3000 h minimum ± 0.5 %F.S. ± 2 digits (at 25 °C ± 5 °C) Auto power off (3 min), Display hold, Battery replacement display Attachements : Half union (for a tube of φ 6 O.D.), and Barb fitting (for a tube of φ 4 I.D.), one piece each.
❈1 : Measurement can be made up to “− 760 mmHg” for 102VH and up to “760 mmHg” for 102GH and 102AH (Accuracy not guaranteed beyond the rated pressure).
Specifications are subject to change without notice. Specifications in this catalog are for reference. The formal specification sheets will be submitted upon request.
COPAL ELECTRONICS
ENVIRONMENTAL CHARACTERISTICS
Test item
Test conditions
Permissible change
98.1 m/s2, 3 directions for 3 times each (packed) ■ OUTLINE DIMENSIONS
Unless otherwise specified, tolerance : ± 0.5 (Unit: mm) POWER DC 3.5V LITHIUM
COPAL ELECTRONICS
MADE IN JAPAN
EXAMPLE OF APPLICATIONS
Measurement of air pressure for a automatic machinery.
Measurement of source pressure from a compressor.
Specifications are subject to change without notice. Specifications in this catalog are for reference. The formal specification sheets will be submitted upon request.

Source: http://www.jinhong.co.kr/2008/product/Seneors/pg100_en.pdf

A-t 2003; 34: 18

a r z n e i - t e l e g r a m m 2003; Jg. 34 , Nr. 2 nicht richtig einlegen oder verlieren den Ring.2 Bei mindes- sen beim Einlegen und Entfernen des Rings eingehalten wer- Waren- tens einer Schwangerschaft besteht der Verdacht, dass der Va-ginalring beim Tamponwechsel unbemerkt entfernt wurde.7Offen bleibt, ob gleichzeitige Verwendung von Tamponsdie Hormonspiegel beeinflusst. Auch über W

Microsoft word - deh 1802 dental hygiene ii.doc

Broward Community College Course Outline ═══════════════════════════════════════════════════════════════════════ STATUS: ACTIVE COMMON COURSE NUMBER: DEH 1802 ___ COURSE TITLE: Dental Hygiene II CREDIT HOURS: CONTACT HOURS BREAK

© 2010-2018 Modern Medicine